Sign In | Join Free | My ledscreensign.com |
|
Brand Name : MSL
Model Number : HX07
Certification : ce,ISO
Place of Origin : China
MOQ : 2
Price : negotiation
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability : 1000 pcs per month
Delivery Time : 7-10 days
Packaging Details : Standard package
Output Power : 32kW
High frequency output : ≧25kHz
kVp Range : 40-150 KV
mA Range : 10-400mA
Exposure Timer Range : 0.00125-6.3s (maximum)
mAs Range : 0.5-320mAs
Tube vertical travel range : ≧750mm
Table height : 660mm
32KW High Frequency Medical Radiographic X Ray Machine MSLHX07
Product description:
An X-ray generator is a device that produces X-rays. Together with an X-ray detector, it is commonly used in a variety of applications including medicine, X-ray fluorescence, electronic assembly inspection, and measurement of material thickness in manufacturing operations. In medical applications, X-ray generators are used by radiographers to acquire x-ray images of the internal structures (e.g., bones) of living organisms, and also in sterilization.
Main Features:
X-ray Tube
Nominal focal spot value: 0.6mm (small focus)/1.2mm (large forcus)
Rotation speed (min-1): 2700rpm@50Hz, 3200rpm@60Hz
Maximum tube voltage: 150kV
Maximum filament current: 370mA (small focus) / 760mA(large focus)
Anode Heat Content: 150kHU (111KJ)
Max rating (0.1s) (kw): 20/46kW@50Hz, 22/50kW@60Hz
Radiographic table
Stand
Tube vertical travel range:≧750mm
Tube transverse travel range: ≧1250mm
Tube rotation around table column: ±135°
Tube rotation about the horizontal axis:+180° to -180°, locked at each 0°, 90°, 180°, 270°
Table
Standard table top size: L2000mm×W740mm
Table height: 660mm
Table top travel, longitudinal: 1000mm (min)
Table top travel, transverse: 160mm (min)
Gird Size: 388mm×464mm (15"×18")
R=10:1, f=100cm, N=40 line/cm
Collimator
Control method: Manual
The average brightness of the light field: >150lux
Wall stand
Minimum focal spot height: 800mm
Vertical height: 2100mm
Vertical travel range: 1200mm (min)
Film size: 8"×10",10"×12",11"×14",14"×14", 12"×15", 14"× 17"
Grid Size: 388mm×464mm (15"× 18")
R=10:1, f=180cm, N=40 line/cm
Product advantages:
Generator
- Tube overload protection
- Tube power availability indicated on generator control desk
- Anatomically Programmed Radiography(APR>768)
Tube
- Dual-focus rotating anode tube
- Large heat capacity
- The most advanced production
- High load ,high speed-up
Integrated tube stand
-The four-way floating tabletop comes with high patient load.Permanent magnet brakes are released. The longitudinalmovement combined with the column travel allow examinationswithout moving the patient.
Bucky stand
-optional vertical motorized movement.
-Standard grid size
-Film size optional
Product specification:
Maximum tube voltage | 150kV |
Focal spot to tabletop/wall stand | 1100mm (min) |
Standard table top size | L2000mm×W740mm |
Table height | 660mm |
Vertical height | 2100mm |
Film size | 8"×10",10"×12",11"×14",14"×14", 12"×15", 14"× 17" |
Product pictures:
![]() |
32KW High Frequency Medical Radiographic X Ray Machine 660mm Images |